Seraglob by Bioswisstec AG info@seraglob.com +41 52 620 33 44 | Fax +41 52 620 33 45

seraglob

Maximo H-SPlus-Taq DNA Polymerase

Hot Start Polymerase with ultra short inactivation time, free of MAB´s. The glycerol-free version is designed for Lyophilization, especially

 

Description:
Maximo H-SPlus Taq DNA Polymerase (recombinant from Thermus aquaticus) catalyzes the polymerization of nucleotides into duplex DNA in 5’→3′ direction in the presence of magnesium. It also possesses a 5’→3′ polymerization-dependent exonuclease replacement activity but lacks a 3’→5′ exonuclease activity. The activation of the enzyme starts immediately at 70°C and requires no increased time in heating or denaturation step. Its activity is blocked at ambient temperature and switched on automatically at the onset of the initial denaturation. The thermal activation prevents theextension of nonspecifically annealed primers and primer-dimer formation at low temperatures during PCR setup.

Features:
– Maximo H-SPlus Taq DNA Polymerase is “inactive” at room-temperature
– When the reaction temperature is greater than 70 °C the Polymerase “jumps” into action
– It is neither blocked by antibodies nor by chemically modification -> ultra-short activation time
– For “high-yield” Hot-Start PCR results
– Multiplex PCR
– PCR setting up at room-temperature
– As sensitive Polymerase for PCR Diagnostics research
– ready-to use for lyopholization when using the HC-Versions

Unit definition: One unit is defined as the amount of enzyme required to incorporate 10 nmoles of dNTP into acid-insoluble material in 30 min at 72°C.

Concentration: 5 u/µl

Storage buffer: 20 mM Tris-HCl, 100 mM KCl, 0.15 mM EDTA, 1 mM DTT, 0.5% Tween-20, 0.5% Nonidet P40, 50% (v/v) Glycerol, pH 8.1

Reaction buffers:
1.) Reaction buffer (10X)” incomplete” (red cap):160 mM (NH4)2SO4, 670mM TrisHCl pH 8,8, 0,1% Tween-20, enhancers
2.) Reaction buffer (10X) “complete” (yellow cap):160 mM (NH4)2SO4, 670mM TrisHCl pH 8,8, 0,1% Tween-20, enhancers, 25mM MgCl2
3.) separate Tube: 100 mM MgCl2

Storage: at -20°C for 24 months, avoid frequent thawing and freezing

Transport:with blue ice or at ambient temperature depending on the destination

Stability tests / Quality control / Comparison
H-SPlus Taq DNA Polymerase is free from endonucleases and primer contamination, positive PCR performance with several templates of Lambda DNA (<= 12 kb) and human placenta DNA (3kb).

ProductDescription
S9400Maximo H-SPlus-Taq DNA Polymerase
200 Units
S9410Maximo H-SPlus-Taq DNA Polymerase
1000 Units
S9410GFMaximo H-SPlus-Taq DNA Polymerase Glycerol free buffered
1000 Units

 

Pricelist

 

Datasheet

Stability Test Report

Material Safety Datasheet